APAR status
Closed as program error.
Error description
DS751A/AIX Customer is getting data corruption If they use ODBC Stage and set in Datastage as binary and DB datatype as CHAR FOR BIT DATA It works with a table definition of : CTF_UNQ_ID CHAR(13) NOT NULL However it fails with a table definition of CTF_UNQ_ID CHAR(13) FOR BIT DATA NOT NULL Engg is suggesting this could be similar to 126131, Please port this patch to DS751A/AIX.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: ALL **************************************************************** PROBLEM DESCRIPTION: Data corruption on loading binary data using ODBC operator **************************************************************** RECOMMENDATION: Install patch for JR29185 ****************************************************************
Problem conclusion
Incorrect length specified for binary column, resulting in data corruption.
Temporary fix
Comments
APAR Information
APAR number
JR29185
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-05-02
Closed date
2008-08-07
Last modified date
2008-08-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
SERVER
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R801 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: