ANS1017E RC-50 failure when performing a Data Protection SAP HANA restore
Symptom
The Data Protection for SAP HANA backup.log shows RECOVERY RECOVER DATA finished with an error.
Cause
Slow or unstable network data transfer between IBM Spectrum Protect server and Data Protection for SAP HANA, and the session is timing out on the IBM Spectrum Protect server side.
Diagnosing The Problem
The IBM Spectrum Protect server activity log may show following error:
ANR8216W Error sending data on socket 73372. Reason 10053.
The server instrument trace shows a slow Network Send.
Resolving The Problem
The TCPWINDOWSIZE value should be adaptable for the network performance. To achieve better performance, set the TCPWINDOWSIZE in the client option file used by Data Protection for SAP HANA to a value of zero:
TCPWINDOWSIZE 0
When you set the value to 0, the server uses the default window size that was set by the operating system.