IBM Support

Calculation explained for -Earliest Next Due Date?(PM.ERLSTWOGENDATE)- field in Maximo Base Services?

Question & Answer


Question

How is the field -Earliest Next Due Date (PM.ERLSTWOGENDATE)- calculated in Maximo Base Services?

Answer

PM.ERLSTWOGENDATE = Earliest next due date for a work order generated from this PM.

This is calculated from the PM tab in the PM application - 'Work Order Information' section

To set the Earliest next work order generation date, the code checks for:

Time Based (PM.nextdate and PM.extdate) and Meter Based Frequency

If it finds any of the above scenarios,namely PM.nextdate or PM.extdate or if its the 'Meter Based Frequency', then it gets the 'Estimated Meter Due Date'.

The calculation will find the earliest meter based due date taking in consideration all meters listed on the PM:

- ASSETMETER - lastreadingdate
- ASSETMETER - average

If no date can be generated for this PMMeter, null will be returned.

As this is a calculated field, this field is not to be found in a table as such.
It is a non-persistent attribute influenced by the above various factors as well as the other related calculated date fields.

This attribute can be found in the PM class under:

java.lang.Object
extended by psdi.mbo.Mbo
extended by psdi.mbo.StatefulMbo
extended by psdi.app.pm.PM

Note: Please keep in mind that if seasonal dates are involved, the calculation will be influenced accordingly.

http://www-01.ibm.com/support/docview.wss?uid=swg21622553

and

For further information on some of the mentioned calculated fields, see also the following related DCF documents:

http://www-01.ibm.com/support/docview.wss?uid=swg21625139 

and

http://www-01.ibm.com/support/docview.wss?uid=swg21701553 

[{"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Component":"Assets","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"6.2.8;7.1.1;7.1.2;7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}},{"Product":{"code":"SSWT9A","label":"IBM Control Desk"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"7.5;7.5.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}},{"Product":{"code":"SSLKTY","label":"Maximo Asset Management for IT"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"6.2.8;7.1.1;7.1.2;7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}},{"Product":{"code":"SSKTXT","label":"Tivoli Change and Configuration Management Database"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"},{"code":"PF027","label":"Solaris"},{"code":"PF010","label":"HP-UX"}],"Version":"6.2.8;7.1.1;7.1.2;7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}},{"Product":{"code":"SS6HJK","label":"Tivoli Service Request Manager"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"","label":"Windows 2003 server"}],"Version":"6.2.8;7.1;7.1.2;7.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]