Error 1067: The process terminated unexpectedly

Troubleshooting


Problem

You may receive the error "Error 1067: The process terminated unexpectedly" when trying to start the Windows service for WebLogic.

Symptom

When trying to start the WebLogic windows service you get an error message stating - Error 1067: The process terminated unexpectedly

Environment


Resolving The Problem

Uninstall the service then edit the InstallService.cmd that you created, since this does not come with WebLogic 9 and add the following variable:

set JAVA_VM=-server

Resave, and run the InstallService.cmd

[{"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"7.1.1;7.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]