Abstract
MQM400 STRMQM FAILS WITH PROBE AL008000 ON OS400 WITH OS
VERSION V6R1M0
Error Description
STRMQM will fail to start on OS version V6R1 having large
sequence number in the journal receiver and following FDC is
generated.
WebSphere MQ First Failure Symptom Report
LVLS :6.0.2.4
Probe Id :-AL008000
Component :- almPerformReDoPass
CMVC level :- p600-204-080428
Job Name :- 402617/QMQM/AMQZXMAX
Major Errorcode :- krcE_UNEXPECTED_ERROR
Probe Type :- INCORROUT
Probe Description :- AMQ6125: An internal WebSphere MQ error
has occurred.
MQM Function Stack
kpiStartup
apiStartup
almPerformReDoPass
xcsFFST
....
..
ExceptID
SPP:0000 :1aefAMQZXMAX QMQM 402617 :c90:153:14
SPP:0x00000c90: C3D7C6F7 F0F5F4
CPF7054
Problem Summary
STRMQM will fail to start on OS version V6R1 having large
sequence number in the journal receiver and following FDC is
generated.
WebSphere MQ First Failure Symptom Report
LVLS :6.0.2.4
Probe Id :-AL008000
Component :- almPerformReDoPass
CMVC level :- p600-204-080428
Job Name :- 402617/QMQM/AMQZXMAX
Major Errorcode :- krcE_UNEXPECTED_ERROR
Probe Type :- INCORROUT
Probe Description :- AMQ6125: An internal WebSphere MQ error
has occurred.
MQM Function Stack
kpiStartup
apiStartup
almPerformReDoPass
xcsFFST
....
..
ExceptID
SPP:0000 :1aefAMQZXMAX QMQM 402617 :c90:153:14
SPP:0x00000c90: C3D7C6F7 F0F5F4
CPF7054
Problem Conclusion
Correction has been done to the condition checking to get the
correct size of the sequence number for all the version V5R3
and greater.
Scheduled for WMQV6.0.2.5
Temporary Fix
Comments
Circumvention
None
PTFs Available
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | No |
Component.................................. | 5724H7206 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R600 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information
Document Information
Modified date:
11 December 2012