IBM Support

RS02491: NULLPOINTEREXCEPTION DURING SYNCHRONIZATION WITH NEWLY ADDED DEPENDENT PROJECTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • For a new rule project that is added to an existing decision
    service with dependancies, it has to stay connected to Decision
    Center while synchronizing the decision service.
    Disconnecting the rule project after publish it to Decision
    Center (keep connection entries) will introduce various errors
    afterwards in Decision Center while extracting project state,
    and pulling the projects from Decision Center into a new
    workspace.
    

Local fix

  • Make sure the rule project is connected to Decision Center
    during the synchronization.
    

Problem summary

  • We have a NullPointerException during synchronization with
    newly added dependent projects
    because if the sync branch is null this causes an NPE later on
    in ProjectBranch
    This can happen if the project was disconnected from Decision
    Center in RuleDesigner
    We need to retrieve the sync from the server project infos
    based on the main project.
    

Problem conclusion

  • The code is fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    RS02491

  • Reported component name

    WS DECISION CTR

  • Reported component ID

    5725B6900

  • Reported release

    881

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-09-06

  • Closed date

    2017-02-16

  • Last modified date

    2017-02-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    WS DECISION CTR

  • Fixed component ID

    5725B6900

Applicable component levels

  • R881 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSQP76","label":"IBM Operational Decision Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"881","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: