IBM Support

RS02400: [DCEC] UNABLE TO SET STRING VALUE UNDER STRUCT VIA A QUERY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Unable to set string values under Struct using a query in the
    Decision Center Enterprise Console.
    
    Following exception is thrown when trying to update an existing
    struct property using query:
    
    Caused by: java.lang.UnsupportedOperationException
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.
    eBasicProperties(BasicEObjectImpl.java:249)
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.eHasSettings(
    BasicEObjectImpl.java:255)
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.eSettings(
    BasicEObjectImpl.java:261)
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.eDynamicSet(
    BasicEObjectImpl.java:1137)
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.eSet(
    BasicEObjectImpl.java:1111)
       at org.eclipse.emf.ecore.impl.BasicEObjectImpl.eSet(
    BasicEObjectImpl.java:1081)
       at ilog.rules.brl.bql.util.IlrQueryWrapperUtils.
    genericStructSet(IlrQueryWrapperUtils.java:62)
    ....
    

Local fix

  • Manually update the Struct property in Compose tab
    

Problem summary

  • Change IlrQueryableElement implementation to be able to update
    the Struct property
    

Problem conclusion

  • The code is fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    RS02400

  • Reported component name

    WDS FOR RULES

  • Reported component ID

    5725B6903

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-25

  • Closed date

    2016-06-17

  • Last modified date

    2016-06-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    WDS FOR RULES

  • Fixed component ID

    5725B6903

Applicable component levels

  • R880 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSQP76","label":"IBM Operational Decision Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 February 2022