  • The RuleInstance object associated with the firing of a
    Sequential rule may have incorrect or missing Tuple references.
    

Local fix

  • Use Decision Engine RetePlus or Fastpath algorithms instead of
    Sequential
    Or use Classic Rule Engine
    

Problem summary

  • The binding of shared variable is not properly propagated
    resulting  in rule not matched
    

Problem conclusion

  • The code is fixed
    