IBM Support

RS01907: WRONG VARIABLE SHARING FOR RULESET PARAMETER or RULESET VARIABLES IN FASTPATH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using the Fastpath algorithm, Ruleset parameters or
    Ruleset variables with the same initial value are considered as
    equivalent.
    This leads to different execution results, depending on the
    chosen algorithm.
    

Local fix

  • Use Sequential or Rete-plus algorithm instead of Fastpath.
    Or specify a different initial value for each variable of the
    same type.
    

Problem summary

  • incorrect detection of equivalence of variables based on their
    intial value
    

Problem conclusion

  • The code is fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    RS01907

  • Reported component name

    WS DECISION SVR

  • Reported component ID

    5725B6901

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-02-20

  • Closed date

    2015-03-06

  • Last modified date

    2015-03-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    WS DECISION SVR

  • Fixed component ID

    5725B6901

Applicable component levels

  • R851 PSY

       UP