IBM Support

RS01026: BUILD AUTOMATION SOMETIMES FAILS TO LOAD THE RULE PROJECT IF THE RULE PROJECT IS THE LAST ONE ON IMPORTPATH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When importing more than 2 projects into the workspace, with the
    rule project to build being the last one on importPath, every
    other build fails with the following exception:
    
    java.lang.IllegalStateException: Failed to find an open rule
    project named <name_of_rule_project> in workspace at
    ilog.rules.studio.automation.IlrAutomator.getRuleProjects
    

Local fix

  • Switching the project order on ImportPath so that the rule
    project to build is at the beginning of the list on the
    ImportPath reduces the chances of encountering this issue.
    

Problem summary

  • The problem occurs with multiple projects because of
    concurrency in parallel build.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    RS01026

  • Reported component name

    WS DECISION SVR

  • Reported component ID

    5725B6901

  • Reported release

    750

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-21

  • Closed date

    2012-07-16

  • Last modified date

    2012-07-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

Applicable component levels

  • R800 PSY

       UP