Error description
Client create a remote server in RAD pointing to remote WAS v8.0.0.4 z/os server, the remote server can be connected without problem, and project can be published to remote server successfully. But client find that immediately after RAD connect to WAS z/os, CPU utilization for the ASRA address space increases considerably, to 15% of ZIIP/ZAPP on Z114/2818 M05. WAS team analyzed client's ZOS dump file and log file, they suspect that the high CPU utilization might be caused by RAD always try to download try to download from '/u/wasv8config/h1basea/h1nodea/AppServer/profiles/default/confi g/temp/logs/sysout' But always get file does not exist error, this increase CPU utilisation.
Local fix
Problem summary
The location of the log files is different for a WebSphere Application Server System Z install than a distributed install. As a result the product is unable to download the log files and this process does not terminate.
Problem conclusion
Code change to halt subsequent downloading processes upon specific failed download attempt. The fix for this APAR is included in Rational Application Developer v8.0.4.3.
Temporary fix
Comments
APAR Information
APAR number
PM93990
Reported component name
RATL APP DEV WI
Reported component ID
5724J1901
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-29
Closed date
2013-10-28
Last modified date
2013-10-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL APP DEV WI
Fixed component ID
5724J1901
Applicable component levels
R804 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
28 October 2013