IBM Support

PM93942: ABEND=S5C6 U0000 REASON=00F10011

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND=S5C6 U0000 REASON=00F10011
    
    SYSTEM COMPLETION CODE=5C6  REASON CODE=00F10011
     TIME=15.22.28  SEQ=34127  CPU=0000  ASID=0081
     PSW AT TIME OF ERROR  078D2000  8000BEA6  ILC 2  INTC 0D
       ACTIVE LOAD MODULE  ADDRESS=00007000  OFFSET=00004EA6
       NAME=CSQ1LOGP
       DATA AT PSW  0000BEA0 - 58F0B0A8  0A0D5840  D2744100
       AR/GR 0: 009CFAC8/0003814F   1: 00000000/845C6000
             2: 00000000/0003814F   3: 00000000/00000495
             4: 00000000/0FE41280   5: 00000000/00006A48
             6: 00000000/009BBFC8   7: 00000000/00076528
             8: 00000000/1043B3F0   9: 00000000/0001B464
             A: 00000000/1043B3F0   B: 00000000/0000E708
             C: 00000000/0001C21B   D: 00000000/0001B21C
             E: 00000000/8000BE74   F: 00000000/00F10011
    .
    The problem occurs when procesing a log-record containing
    an IRH9 which has the v6compat bit set in the MMC_SEG_HDR1
    segment.
    This means that CSQ1LEXT does not set pMhdr and therefore
    lData (length of data) is not calculated correctly, which
    results in the abend.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0 using the log print *
    *                 utility CSQ1LOGP.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: CSQ1LOGP run with EXTRACT(YES) abends   *
    *                      5C6-00F10011, or 5C6-00F10010 or        *
    *                      0C4-00000010.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    While processing a log record for the insert of an IRH8 or IRH9
    message, the MMC_SEG_HDR1 segment is not correctly recognised if
    any flags (for example fv6compat) are set in the segment type
    field in addition to the datatype.
    As a result pMHDR is not correctly calculated resulting in an
    abend.
    

Problem conclusion

  • CSQ1LEXT has been changed to address the datatype correctly and
    therefore correctly set pMHDR.
    100Y
    CSQ1LEXT
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM93942

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-07-26

  • Closed date

    2013-08-29

  • Last modified date

    2013-10-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK97121

Modules/Macros

  • CSQ1LEXT
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UK97121

       UP13/09/27 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 October 2013