Error description

  • After RRS failure, ABEND0D6 occurs at CSQIRRSI which is trying
    to issue an Express_UR_Interest.
    The recovery processing does not undo the MQGET process, but it
    returns to the application with MQRC 2195.
    The application then issues commit which results in message
    lost. In this situation the message should have been backed out
    before returning the application with MQRC 2195.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 0 Modification 1.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: MQGET with MQGMO_SYNCPOINT for a shared *
    *                      queue completes with MQRC 2195          *
    *                      (MQRC_UNEXPECTED_ERROR) and the message *
    *                      is removed from the queue.              *
    *                      An underlying abend occurs during the   *
    *                      get processing, such as, but not        *
    *                      limited to, 0D6-00000027 (RRS abend).   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An MQGET is being processed, and the message has been moved to
    the uncommitted get queue. As this is for a shared queue, the
    ETRQS and ETROP control blocks have been created.
    After the underlying abend occurred, the recovery processing
    that takes place in CSQIMGES does not undo the creation of the
    ETRQS and ETROP blocks, nor does it move the message back to the
    queue from the uncommitted get queue.
    

Problem conclusion

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

  • The code has been changed to correctly track the message that
    was put on the uncommitted get queue as part of the MQGET call
    and back it out correctly if required.
    

APAR Information

  • APAR number

    PM92039

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    010

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-06-28

  • Closed date

    2013-07-23

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK96064

Modules/Macros

  • CSQEMGEB CSQEMGEC CSQEMGEK CSQEMGET CSQESYN1
    CSQETHDP CSQIMGES
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R010 PSY UK96064

       UP13/08/23 P F308 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 September 2013