A fix is available
APAR status
Closed as program error.
Error description
Changes made by another user is not reflected when module is opened, where it was earlier open with display set to false. Steps to reproduce: - Create 2 modules, A and B - Create 2 users, U1, U2. - Create links from A to B - Create a traceability column in B to show in-link details and save it as View V. - Login to DOORS as U2. - Open Module B in Exclusive Edit and load View V. - Login to DOORS as U1. - Open A in shared edit mode, make some changes, save and close. - From the session of U2, open A in Read-only mode. Changes made by U1 are not shown. Work-around - Close module A and re-open, changes are shown. Or, open in a different edit mode.
Local fix
Problem summary
Changes made by another user is not reflected when module is opened, where it was earlier open with display set to false. Steps to reproduce: - Create 2 modules, A and B - Create 2 users, U1, U2. - Create links from A to B - Create a traceability column in B to show in-link details and save it as View V. - Login to DOORS as U2. - Open Module B in Exclusive Edit and load View V. - Login to DOORS as U1. - Open A in shared edit mode, make some changes, save and close. - From the session of U2, open A in Read-only mode. Changes made by U1 are not shown. Work-around - Close module A and re-open, changes are shown. Or, open in a different edit mode.
Problem conclusion
The code has been changed so that the changes are now visible in this scenario.
Temporary fix
Close module A and re-open, changes are shown. Or, open in a different edit mode.
Comments
APAR Information
APAR number
PM88856
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-13
Closed date
2013-11-07
Last modified date
2013-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R951 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
01 November 2021