Error description

  • It is currently not possible to correlate CICS TYPE 110 SMF
    records with WebSphere MQ Type 116 SMF records.
    
    It is however possible to correlate CICS Type 110 SMF records
    with DB2 Type 101 SMF records, and use the CICS Performance
    Analyser to produce reports for CICS/DB2 transactions.
    
    CICS sets the 27 byte network UOWID and extracts from this a 22
    byte correlation token which it passes to DB2 and which DB2 in
    turn sets in DB2 Type 101 SMF records.  CICS also passes the 27
    byte network UOWID to WebSphere MQ so that WebSphere MQ can
    extract from it the 22 byte correlation token and set it in
    WebSphere MQ Type 116 SMF records.  The QWHCTOKN field already
    exists in the Type 116 SMF records however, WebSphere MQ
    currently does not store and set this correlation token field.
    
    This APAR is being raised so that WebSphere MQ can set this
    correlation token.
    

Local fix

  • No local fix available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Websphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: WebSphere MQ Type 116 SMF records       *
    *                      cannot be correlated with CICS Type 110 *
    *                      SMF records.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Type 116 SMF records are used for processing type accounting
    records. As these records do not correlate with CICS type 110
    SMF records, this restricts the ability to correlate this
    accounting data for CICS/WebSphere MQ transactions. For example
    this results in CICS Performance Analyzer not being able to
    adequately generate reports for these transactions.
    
    This is due to the accounting token in the type 116 SMF records
    (QWHCTOKN), being set correctly, as to allow these to be
    correlated with the CICS Type 110 SMF records.
    

Problem conclusion

Temporary fix

Comments

  • The accounting token, QWHCTOKN, in the WebSphere MQ SMF records
    has been altered, to be set to the correct value, allowing
    correlation.
    
    --------------------Info Center Changes-------------------------
    Common WebSphere  MQ SMF header
    At Location: WebSphere MQ > Monitoring and performance >
      Monitoring performance and resource usage on z/OS >
      Interpreting WebSphere MQ accounting data
    
    Page: http://publib.boulder.ibm.com/infocenter/wmqv7/v7r1/topic
          /com.ibm.mq.doc/zs12000_.htm
    
    Change:
    Below the paragraph starting "The QWHC data gives you
    information" add the following :
    
     "The QWHC section is completed only for subtype 0 records. The
    equivalent information is present in the thread identification
    record for subtype 1 and 2 records."
    
    ---------------------------------------------------------------
    
    Add a new page with title:
    "Combining CICS and WebSphere MQ performance data"
    At Location: WebSphere MQ > Monitoring and performance >
     Monitoring and performance > Monitoring performance and
     resource usage on z/OS > Interpreting WebSphere MQ accounting
     data
    
    Contents:
    The common WebSphere MQ SMF header type accounting record
    section, QWHCTOKN, is used to correlate CICS type 110 SMF
    records with WebSphere MQ type 116 SMF records.
    
    CICS generates an LU6.2 unit-of-work token, for each CICS task.
    The token is used to generate an accounting token which is
    written to QWHCTOKN in the correlation header of subtype zero
    records. Details are also written to the WTIDACCT section in
    subtype 1 and 2 records. The accounting token enables
    correlation between CICS and WebSphere MQ performance data for
    a transaction.
    

APAR Information

  • APAR number

    PM82576

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-02-12

  • Closed date

    2013-06-07

  • Last modified date

    2013-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK94939

Modules/Macros

  • CSQMCPRH CSQWVAPR
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UK94939

       UP13/07/24 P F307

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 August 2013