IBM Support

PM79000: BATCH NOT COMMITTED AFTER BATCHLIM BYTES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A channel sending messages in syncpoint does not correctly close
    the batch when BATCHLIM bytes have been transmitted.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Channel batch not committed after       *
    *                      BATCHLIM bytes have been transferred.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When messages are sent across a channel, and the number of bytes
    transmitted in the current batch exceeds the channel's BATCHLIM
    setting the batch should be closed, causing a confirm request to
    be sent to the remote channel, and any uncommitted messages to
    be committed. However, if the channel is using a large (>32K)
    transmission buffer (for example, when sending large messages)
    this does not occur correctly, and the batch is not closed until
    BATCHSZ messages have been sent or the transmission queue has
    been empty for more than BATCHINT seconds.
    

Problem conclusion

  • rriSendData is changed to correctly update the count of bytes in
    the current batch when using a large transmission buffer, so
    that the batch is correctly closed if the transmission of a
    message causes the number of bytes sent to exceed BATCHLIM.
    100Y
    CSQXRMTR
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79000

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-12-12

  • Closed date

    2013-01-10

  • Last modified date

    2013-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK90868

Modules/Macros

  • CSQXRMTR
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UK90868

       UP13/02/05 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.