  • This is created from escalation RATLC01815763
    
    Client is using 7.5.5.1. They find out that
    while doing a copy/paste of lifelines between two interactions
    owned by the
    same capsule ; the paste action creates a new redundant capsule
    parts. (named copy_1_xxx)
    
    They would expect that the same capsule parts are used in the
    two cases as the lifelines ?refer to same model elements.
    
    
    Steps to reproduce
    1 - Create a C++ Model
    2 - Add two new Capsules
    3 - Add two Sequence Diagram into Capsule1 =? it creates 2
    Interactions.
    4 - Create a lifeline for capsule2:Capsule2 into Interaction 1
    5 - Copy the lifeline capsule2:Capsule from Interaction1 into
    Interaction2
    =? Copy_1_capsule2:Capsule2
    Client expected capsule2:Capsule2
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    while doing a copy/paste of lifelines between two
    interactions owned by the
    same capsule the paste action creates a new redundant
    capsule parts.
    

Problem conclusion

  • The lifeline if copy/pasted to the same Collaboration the
    Represents property will not be copy/pasted. This behaviour
    would be controlled by a new Preference under
    Window-?Preferences-?Modeling-?UML Diagrams-?Sequence and
    Communication.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM78346

  • Reported component name

    RSA REALTIME

  • Reported component ID

    5724G4701

  • Reported release

    755

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-04

  • Closed date

    2013-06-14

  • Last modified date

    2013-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RSA REALTIME

  • Fixed component ID

    5724G4701

Applicable component levels

  • R755 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS5JSH","label":"Rational Software Architect RealTime Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 June 2013