Error description
In Rhapsody C 7.6.1.1 there is the loss of a flow connector between the ports of two parts in an Internal Block Diagram if you do the following steps: 1. Create a SysML project with a Block Definition Diagram, and add two blocks, A and B. 2. Add two standard ports each to blocks A and B, to make ports A1, A2, B1 and B2. 3. Create a flow from port A1 to port B1. 4. Create an Internal Block Diagram. 5. Drag and drop blocks A and B onto the IBD and create Parts from them. The flow between A1 and B1 should appear on the diagram. 6. Create a new flow between ports A2 and B2 on the IBD. 7. Save, close and reopen Rhapsody and the SysML project. The flow from A1 to B1 will not appear on the IBD anymore.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Loss of flow connector from Internal Block Diagram when restarting Rhapsody
Problem conclusion
The flow between the ports of the new created Parts in not valid anymore and therfore it is removed from diagram.
Temporary fix
Comments
APAR Information
APAR number
PM77844
Reported component name
TLOGIC RHAPSODY
Reported component ID
5724V74RP
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-27
Closed date
2013-03-21
Last modified date
2013-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC RHAPSODY
Fixed component ID
5724V74RP
Applicable component levels
R761 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
06 January 2022