Error description
Configuration: -------------- Tool = Rational System Architect Version = 11.4.2.1 Description: ------------ Not possible to use Align Over in the 'Introduction' Chapter/Tab How to reproduce: ----------------- 1. Create a new encyclopedia with the following (working but not complete) USRPROPS: RENAME DEFINITION 'User 1' To 'Defect test 1' RENAME DEFINITION 'User 2' To 'Defect test 2' RENAME DEFINITION 'User 3' To 'Defect test 3' DEFINITION 'Defect test 1' { CHAPTER 'Introduction' LAYOUT { ALIGN OVER } PROPERTY 'Test in Introduction' {EDIT TEXT} } DEFINITION 'Defect test 2' { NODESC CHAPTER 'Introduction' LAYOUT {ALIGN OVER} PROPERTY 'Description' { EDIT Text} PROPERTY 'Test in Introduction' {EDIT TEXT} } ==? 'Defect test 1' shows that trying to add a property creates a second Introduction tab. This is already reported in APAR PM74599. Note that ALIGN OVER is not in effect for the first Introduction tab. 'Defect test 2' shows a possible Workaround for this issue. However, any previous Descriptions will be made invisible Create a 'Defect test 3' definition, you see by default a new user defined definition, no longer has ALIGN OVER for the Description in the Introduction tab.
Local fix
Problem summary
"Defect test 1" shows the fact that the default "Defect test 2" shows that trying to add a property creates a second Introduction tab. "Defect test 3" shows the Workaround for "Defect test 2" "Defect test 4" shows that the Workaround for "Defect test 2" combined with ALIGN OVER does not work "Defect test 5" shows a possible Workaround for this issue.
Problem conclusion
"Defect test 1" shows the fact that the default layout no longer use ALIGN OVER - this was never the default, hence the existence of the ALIGN OVER keyword in the first place "Defect test 2" shows that trying to add a property creates a second Introduction tab. - fixed "Defect test 3" shows the Workaround for "Defect test 2" - still ok "Defect test 4" shows that the Workaround for "Defect test 2" combined with ALIGN OVER does not work - fixed "Defect test 5" shows a possible Workaround for this issue. - still ok
Temporary fix
Comments
APAR Information
APAR number
PM77158
Reported component name
TLOGIC SYS ARCH
Reported component ID
5724V68SA
Reported release
B40
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-15
Closed date
2013-10-09
Last modified date
2013-10-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYS ARCH
Fixed component ID
5724V68SA
Applicable component levels
RB42 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
09 October 2013