IBM Support

PM77054: DOUBLE-BYTE CHARACTERS ARE MISSED DURING PLAYBACL

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • With RFT 8.2.x, Some of the double-byte characters are missed
    during playback.
    
    However a workaround exists by,
    Increase the value for 'Delay before key down' from default
    0.001 to 0.1
    ('Delay before key down' is in Window ? preferences ? playback ?
    Delays page)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Some double-byte characters are missed during playback.
    

Problem conclusion

  • for playback of double-byte characters, we let the IME
    process the key event. There is no return from the IME and
    hence we do not wait for a response. Since we are dependent
    on the IME for a successful response and this is not
    possible, nothing can be done from the RFT end to ensure
    that the double-byte character is played back in the default
    time. In the case where RFT starts to process the next event
    and if IME has not processed the event for the double-byte
    character, the double-byte character is lost.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM77054

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    811

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-13

  • Closed date

    2013-08-26

  • Last modified date

    2013-08-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSJMXE","label":"Rational Functional Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
29 October 2021