Error description

  • After the first use, diagram windows can open and remain very
    small when System Architect is used with the French language
    edition of Windows XP
    
    Procedures to reproduce:
    1) On the French language version of Windows XP, open System
    Architect 11.4.2.1.
    2) Open a diagram
    3) The diagram opens up with the correct size.
    4) Close SA.
    5) Restart SA, and open the same diagram. Note the diagram
    windows open very small and are not resizable
    
    Expected Results: the diagrams should take the full extent of
    that area of SA's window
    
    Actual Results: the diagrams take up maybe one fifth of the area
    of SA's main window
    
    Workaround:
    
    In the sa2001.mst file  under the [SystemArchitect section] add
    the line:
    SA2001 version=11111
    
    Note: (Windows 7) this WA also causes the user to never be able
    to save a customized toolbar to persist to the next session
    because if you set the SA version to something other than the
    current version number SA will assume it needs to upgrade the
    toolbar file so it will load the default, which works but of
    course you loose your customizations.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Invalid entries in toolbar file are causing SA not the
    properly initialize the diagram window.
    

Problem conclusion

  • The toolbar file is being saved with an invalid parameter
    value for one tool.  This causes an error which is not
    handled properly leading to improper initialization of the
    diagram window.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM75987

  • Reported component name

    TLOGIC SYS ARCH

  • Reported component ID

    5724V68SA

  • Reported release

    B42

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-26

  • Closed date

    2013-06-14

  • Last modified date

    2013-08-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC SYS ARCH

  • Fixed component ID

    5724V68SA

Applicable component levels

  • RB42 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
29 August 2013