  • Customer is trying to record a socket test for managed
    application but when he starts a new recording, the application
    is not launched. RPT shows current status :Active and then to
    Terminated.
    
    TSE had a remote session to look at the issue at customer end. I
    could also replicate the problem on a VM with RPT 8.2.1.4
    Steps followed:
    1. Created Test from New Recording
    2. Select Socket Test
    3. Provide application path as C:\Windows\System32\Notepad.exe.
    4. Click Next -? Finish.
    First time the application is launched but in subsequent tries
    of above steps, application is not launched.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    While trying to record a socket test for managed
    application, the application is not launched. RPT shows
    current status as Active and then to Terminated.
    

Problem conclusion

  • Fixed indirectly in 8.3.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM74685

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    821

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-10

  • Closed date

    2012-10-23

  • Last modified date

    2012-10-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

  • R821 PSN

       UP