IBM Support

PM72920: Wrong AUTOSAR behaviour in Rhapsody while connecting 2 ports

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Headline:
    Wrong AUTOSAR behaviour in Rhapsody while connecting 2 ports
    
    
    Abstract:
    Attempts to draw an AssemblySwConnector results in wrong AUTOSAR
    behaviour
    
    
    APAR Error Description:
    
    In the attached AUTOSAR document, From the end of Pg22, we can
    see that If the connection is between component prototypes on
    the same hierarchy level, then AssemblySwConnectors need to be
    used. However, if the link is between Parent/Child, then
    DelegationSwConnectors ought to be used.
    
    In Rhapsody, AssemblySwConnectors are being used at the
    Parent/Child level as depicted in the attached sample model.
    This behaviour is wrong.
    
    
    
    Local fix:
    The WA is to draw the DelegationSwConnector when Parent/Child
    relationship is involved between the component prototypes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Wrong AUTOSAR behaviour in Rhapsody while connecting 2 ports
    

Problem conclusion

  • Fixed in 7.6.1.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM72920

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-14

  • Closed date

    2012-12-13

  • Last modified date

    2012-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R761 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
29 October 2021