IBM Support

PM71702: Drop-down list box control pointing to short string fields do not allow empty value if keyboard is used on CQWeb

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Value of short string fields with Drop-down list box control
    could not be emptied when using the backspace of keyboard
    instead of the mouse on CQWeb.
    
    Steps to reproduce:
    1- Create a new Short string field; name it: 'Text' on record
    Defect on the DefectTracking schema.
    2- Add Constant list values to the field.
    3- Update the record form adding the new filed as a Drop-down
    list box control.
    4- Check schema in and upgrade database.
    5- Log in CQWeb, submit or modify a record, depends on the form
    that was updated.
    6- Select a value in the field 'Text' and save record.
    7- Modify same record and delete the selected value in the field
    'Text' using backspace on keyboard not the mouse to drop down
    the list.
    As there is no blank line in the list of values, you will be
    prompted with warning: 'The value entered is not valid'. Click
    OK and save, the deleted value still exists.
    If you have a blank line in the list of values, no warning is
    prompted and same behavior, i.e. saving the record the deleted
    value still exists.
    
    This is not the same behavior in CQWeb pre v. 8.0.0.x and on CQ
    Windows client. Emptied value with the keyboard is saved
    correctly.
    Reproduced on CQ 8.0.0.3 both browsers; IE and FF.
    
    Attached is set of dbs ready with the field 'Text' to reproduce;
    DB.zip
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    ClearQuest Web short string fields with drop-down list box
    controls can not be made blank when using your keyboard's
    backspace key rather than your mouse. If the field has been
    made blank and is not in the list of values, you will be
    prompted with warning: "The value entered is not valid".
    After Clicking "OK" and "Save", the value which was deleted
    still exists.
    

Problem conclusion

  • A fix is available in ClearQuest 8.0.0.5.
    
    Clearing ClearQuest Web short string fields in drop-down
    list box now has consistent behavior when using both a mouse
    and a keyboard.  If the field has been made blank via a
    backspace, clicking "Save" successfully removes the deleted
    value. This makes it consistent with ClearQuest Web
    7.1.2.x.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM71702

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-08-28

  • Closed date

    2012-12-15

  • Last modified date

    2012-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R800 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]