APAR status
Closed as program error.
Error description
There is a problem with using the EST wizard for a XML Transformation project with RDZ 8.0.3.2. Names in -enum fields end with an 'X' now, while they were unchanged in RDZ 7.6. Example of a generated copybook * A value of X'00' indicates an instance of structure 'TEST0' in * file 'OutpuI06.cpy'. * A value of X'01' indicates an instance of structure 'TEST1' in * file 'OutpuI09.cpy'. * 03 MYTEST-enum PIC X DISPLAY. * 88 TEST0X VALUE X'00'. * 88 TEST1X VALUE X'01'. With RDZ 7.6 it would look like this: * A value of X'00' indicates an instance of structure 'TEST0' in * file 'OutpuI06.cpy'. * A value of X'01' indicates an instance of structure 'TEST1' in * file 'OutpuI09.cpy'. * 03 MYTEST-enum PIC X DISPLAY. * 88 TEST0 VALUE X'00'. * 88 TEST1 VALUE X'01'. This issue has been fixed for CICS Assistants with APAR PM47134. This fix has to be backported in RDz.
Local fix
Problem summary
See error description.
Problem conclusion
The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.0.3.4 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM69739
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
803
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-27
Closed date
2012-12-13
Last modified date
2012-12-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R803 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: