IBM Support

PM68302: ClearQuest Web does not return error when link is failed to update in DOORS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM Rational ClearQuest Web does not return error when link is
    failed to update in IBM Rational DOORS due to the following
    limitation with ClearQuest DOORS integration:
    
    -There is an exclusive lock is on the requirement module. Users
    should close the module in DOORS client when adding/removing
    links from the ClearQuest Web client. Otherwise, the backlink on
    the requirement module won?t be created or removed.
    
    -Users should have an ?modify? permission on the requirement
    module. Otherwise, the backlink on the requirement module won?t
    be created or removed when adding/removing links from the
    ClearQuest Web client.
    
    Steps to reproduce:
    
    Adding a link from ClearQuest Web
    1. Open a module in a DOORS client.
    2. Modify a record in a ClearQuest Web client.
    3. Go to Links tab and add Implements Request and select an
    object in the DOORS module in step 1.
    4. Save the record.
    5. Open the DOORS module. Notice link to a ClearQuest is not
    created.
    
    Removing a link from ClearQuest Web
    1. Make sure a module is not opened in a DOORS client.
    2. Modify a record in a ClearQuest Web client and add Implements
    Request in Links tab.
    3. Open the module in a DOORS client and make sure link is
    created.
    4. Keep the module open.
    5. Modify the same record in a ClearQuest Web client and remove
    the link added in the step 2.
    6. Check the module in a DOORS client. The link is not removed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ClearQuest Web                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When saving a ClearQuest Web record that creates an OSLC     *
    * link to a DOORS record, if the back link creation in DOORS   *
    * fails, there is no indication seen by the user.              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearQuest 9.0.1.3
    To prohibit ClearQuest Web from saving a record unless the OSLC
    back link creation is successful, the following option can be
    set in cqSiteConfig.pref:
    appOpt$failCommitIfBacklinkCreationFails": "yes",
    When this option is set, ClearQuest will wait for a positive or
    negative response from the OSLC friend before a record will be
    saved.  This can negatively impact performance.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM68302

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-07-06

  • Closed date

    2018-05-09

  • Last modified date

    2018-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R712 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: