IBM Support

PM68165: THE ODBC INTERFACE OF TM1 10.1.0 AND TM1 10.1.0 FP1 SERVER FOR IBM AIX IS BROKEN

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The ODBC interface of both TM1 10.1.0 and TM1 10.1.0.1 aka TM1
    10.1.0 FP1 Server for IBM AIX is broken.??????In an IBM AIX LPAR
    the customer installed ??- 64-bit TM1 9.5.2 Server for IBM
    AIX??- 64-bit unixODBC ODBC Driver Manager??- 64-bit Oracle
    Instant Client ODBC Driver Version 11????The customer configured
    the ODBC Connection. ??It worked.??????They uninstalled 64-bit
    TM1 9.5.2 Server for IBM AIX.??They installed 64-bit TM1 10.1.0
    Server for IBM AIX.????It works with the ODBC test tool
    bin64\odbc_test.exe shipped with 64-bit TM1 10.1.0 Server for
    IBM AIX. But when using the TI Editor to preview a valid SQL
    query, it fails with the error message:??   TM1??   Unable to
    Open Connection to Database??????And in the TM1 server message
    logfile tm1server.log they found the corresponding error
    lines:????3866 [11] ERROR   2012-07-02 15:11:10.711   TM1.SQLAPI
      01000[unixODBC][Driver Manager]Can't open lib
    '/opt/IBM/cognos/oracle/libsqora.so' : file not found?? ??3866
    [11] ERROR   2012-07-02 15:11:10.711   TM1.SQLAPI   E16) Cannot
    connect to ODBC data source "RT70_DEV"  01000[unixODBC][Driver
    Manager]Can't open lib '/opt/IBM/cognos/oracle/libsqora.so' :
    file not found????3866 [11] ERROR   2012-07-02 15:11:10.711
    TM1.SQLAPI   08003[unixODBC][Driver Manager]Connnection does not
    exist??????The customer upgraded from 64-bit TM1 10.1.0 Server
    for IBM AIX to 64-bit TM1 10.1.0.1 aka TM1 10.1.0 FP1 Server for
    IBM AIX, but to no avail: ??The error persists.??
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Please upgrade to IBM Cognos TM1 10.1.1 or IBM Cognos TM1    *
    * 9.5.2 FP3                                                    *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM68165

  • Reported component name

    TM1 TURBO INTEG

  • Reported component ID

    5724W49TI

  • Reported release

    952

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-07-04

  • Closed date

    2012-09-12

  • Last modified date

    2012-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TM1 TURBO INTEG

  • Fixed component ID

    5724W49TI

Applicable component levels

  • RA11 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5.2","Edition":"","Line of Business":{"code":"","label":""}}]