A fix is available
APAR status
Closed as program error.
Error description
Attempts to open the Comparator for a VP from the network result in: Error on page. The customer can search manually for the log, but on my side clicking OpenComparator only yields the error message. Reproduced in-house STEPS TO REPRODUCE Map a network drive with admin credentials. Create a project on a network drive, either on a mapped drive or UNC path. Record a script that types characters in Notepad. Insert a DataVP. Observe that the VP passes at the first playback. Playback again in such a way that the VP fails. Click OpenComparator in the HTML log in IE. Observe the error in the left bottom: Error on page. CONFIGURATION Robot 7.0.3.8 IE8 Win7 x86 RobotStyleSheet.xsl in Rationa; Test folder identical with xsl in Log folder (modified date and size are identical)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Attempts to open the Comparator for a VP from the network result in: Error on page. The customer can search manually for the log, but on my side clicking OpenComparator only yields the error message. Reproduced in-house STEPS TO REPRODUCE Map a network drive with admin credentials. Create a project on a network drive, either on a mapped drive or UNC path. Record a script that types characters in Notepad. Insert a DataVP. Observe that the VP passes at the first playback. Playback again in such a way that the VP fails. Click OpenComparator in the HTML log in IE. Observe the error in the left bottom: Error on page. CONFIGURATION Robot 7.0.3.8 IE8 Win7 x86 RobotStyleSheet.xsl in Rationa; Test folder identical with xsl in Log folder (modified date and size are identical) ATTACHMENT RobotLogStyleSheet.xsl QUESTION How can you open the Comparator when the project's location is on a network drive?
Problem conclusion
UNC path and mapped network path was not handled earlier by OpenComparator function. Added code to handle the above
Temporary fix
Comments
APAR Information
APAR number
PM65166
Reported component name
RATIONAL ROBOT
Reported component ID
5724G2400
Reported release
703
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-22
Closed date
2012-09-06
Last modified date
2012-09-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATIONAL ROBOT
Fixed component ID
5724G2400
Applicable component levels
R703 PSN