IBM Support

PM65058: RFT8211 iFix001 : Web Application control disabled return Object Not Found Exception

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Env
    RFT8211 iFix001
    Browser : IE8
    AUT Web application
    OS: Win XP SP3 / Win 7
    
    Problem description:  The getProperty(), getProperties() (and
    other methods that the customer listed in the description of the
    issue below) would fail to find the object if it's disable.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The RFT playback would throw an objectNotFoundException for
    GUI actions on controls that are disabled as it doesn't make
    sense to perform actions on an object which is not available
    to be modified. However, this logic doesn't hold good when
    we perform the getter actions on a disabled control and we
    should still be able to retrieve the values even though the
    control itself is disabled. Rectified this logic to return
    appropriate values for that getter calls.
    

Problem conclusion

  • All the getXXX() function implementation has been changed to
    provide appropriate values for the disabled controls instead
    of throwing ObjectNotFoundException
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM65058

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    821

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-21

  • Closed date

    2012-08-08

  • Last modified date

    2012-08-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RAT FUNC TESTER

  • Fixed component ID

    5724G2503

Applicable component levels

  • R821 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSJMXE","label":"Rational Functional Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"821","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 October 2021