Error description

  • SAXT lines move on diagram when adding object to it
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    if pool in lane and adding symbol, arrow lines are reset to
    orthogonal which reroutes them through symbols.
    

Problem conclusion

  • Arrow lines are not reset to orthogonal. In 11.4.2.1 there
    is a setting in the web.config file:
    
    ?add key="arrowStyle" value=""/?
    
    Setting the value to N will fix this issue. The lines will
    not be moved.
    
    value options include B (bezier, C (cascading), P (polyline,
    blank (cascading) and N for none
    
    
    B - Bezier
    The link segments are Bezier curves. Each two adjacent
    segments share a control point. The joins between segments
    are always kept smooth.
    
    C - Cascading (which is the default)
    The link consists of straight line segments. All segments
    are either horizontal or vertical, where each two adjacent
    segments are orthogonal one to the other.
    
    P - Polyline
    The link consists of straight line segments.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM64486

  • Reported component name

    TLOGIC SYS ARCH

  • Reported component ID

    5724V68SA

  • Reported release

    B41

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-11

  • Closed date

    2012-09-28

  • Last modified date

    2012-09-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC SYS ARCH

  • Fixed component ID

    5724V68SA

Applicable component levels

  • RB41 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.4.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]