A fix is available
APAR status
Closed as program error.
Error description
From a Linux based console, the job will succeed if thew Windows-based agent is run 'as a Service' but fails if run in 'user mode'.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** When agent is running with user mode on Windows7/Win2008R2, console on Linux/Unix connects to agent, the socket needs a relative long time to be ready.but current design will time out.
Problem conclusion
Adding more times to get the socket Ready status
Temporary fix
Comments
APAR Information
APAR number
PM63830
Reported component name
BUILD FORGE EE
Reported component ID
5724S2701
Reported release
713
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-03
Closed date
2012-09-28
Last modified date
2012-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUILD FORGE EE
Fixed component ID
5724S2701
Applicable component levels
R713 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSB2MV","label":"Rational Build Forge"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.3","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
28 October 2021