A fix is available
APAR status
Closed as Permanent restriction.
Error description
RFT8211 OS Win XP SP3 AUT: Nested domain (Eclipse -? Swt browser -?Java Applet) Problem description: Customer have an application with 3 level nested domains. We provided with a fix for 'Eclipse -? Swt browser -?Java Applet' on top of RFT821. That seemed to work well but when they upgraded to RFT 8.2.1.1 (where the test fix available out of the box) - RFT 8211 is unable to recognize the control at the last third level domain, which is applet.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** RFT recording : Nested domain (Eclipse -? Swt browser -?Java Applet) does not work with RFT
Problem conclusion
Here is the summary of the two issues reported on this escalation: 1) In the nested domain (Eclipse -? Swt browser -?Java Applet) structure, nothing gets recorded in the Java Applet control. This has been resolved by properly packing the customer's application. The detailed solution is documented in the defect RATLC01538395, please refer the update "2/27/2012 11:46:56 AM" 2) Application under test crash - the crash appears to fixed by using the enabled JRE in the RFT. The customer was launching the application using a Window batch file which was using a default JRE from the PATH, ant it was NOT enabled in the RFT. The solution is - set a desired JRE path in the command prompt before starting a application, otherwise enable the default JRE that was used by the AUT. Customer has confirmed without any fixes the customer is up and running. The customer has requested to close this defect as no fix required.
Temporary fix
Comments
APAR Information
APAR number
PM58742
Reported component name
RAT FUNC TESTER
Reported component ID
5724G2503
Reported release
811
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-22
Closed date
2012-05-15
Last modified date
2012-05-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSJMXE","label":"Rational Functional Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
28 October 2021