IBM Support

PM56178: error while adding widgets to data grid RBD 8012

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • the following error is thrown while tyring to add a widget to a
    datagrid:
    Could not publish checkbox event
    
    ('eze$$grid1',[object HTMLInputElement])
    TestGridSelection3.html?contextKey=30:18694 onclick([object
    MouseEvent])
    TestGridSelection3.html?contextKey=30:1
    
    
    document.getElementById(id).eze$$widget is null
    [CRRUI2095E] Could not find the EGL function calls leading to
    this error
    
        DojoButton.handleEvent() at line 18694
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    In RBD 8012, all the widgets which are consisted by table
    inside a gridLayout will be mistakenly destroyed. For
    example, the DataGrid inside a GridLayout will be destroyed,
    which makes the event of checkbox throw exception.
    

Problem conclusion

  • In RBD 8014 and 85, the GridLayout will only destroy its own
    cell and won't affect its children widgets.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM56178

  • Reported component name

    RATL BUS DEV

  • Reported component ID

    5724S5000

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-17

  • Closed date

    2012-10-08

  • Last modified date

    2012-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL BUS DEV

  • Fixed component ID

    5724S5000

Applicable component levels

  • R801 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]