APAR status
Closed as program error.
Error description
When using a fact filter like Measure > 1000 in Report Studio, the runtime increases dramatically. Without the filter the report gets finished within a few seconds. With the filter set the report needs up to an hour or more to finish. It makes no difference if a filter function or detail filter is used. When a summary filter is used, filtering is not applied at all. Running such reports also creates a huge workload on the TM1 Server. The package is setup to use DQM.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos TM1 10.1 Fix Pack 1. * * * * Configuration Instructions: * * 1). Add these two parameters in tm1s.cfg * * CognosMDX.AggregateByAncestorRef=true * * CognosMDX.PrefilterWithPXJ=true * * * * 2). Under BI install, in qfs_config.xml, set * * "UseProviderCrossJoinThreshold" value="1000" * * Location of the file : * * <BI_install>\configuration\qfs_config.xml. * * * * <provider name="TM1OlapODPXQE" libraryName="tm1odpxqe" * * connectionCode="TM"> * * <connectionExpirationThreshold value="300000"/> * * <providerDetails> * * <parameters> * * <parameter * * name="UseProviderCrossJoinThreshold" value="1000"/> * * * * Restart BI service. * ****************************************************************
Problem conclusion
Code Fix
Temporary fix
Comments
APAR Information
APAR number
PM55300
Reported component name
COG8 BI REPORT
Reported component ID
5724W12RS
Reported release
A11
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-04
Closed date
2013-02-21
Last modified date
2013-02-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COG8 BI REPORT
Fixed component ID
5724W12RS
Applicable component levels
RA10 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A11","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
21 February 2013