IBM Support

PM54084: Parent Project hangs when child .runwait project with adaptor link fails

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running a chained project configured with an Adaptor Link
    and executed with .runwait, when the adaptor fails, the parent
    project hangs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    .runwait waits forever for an non-existed build of failed
    adaptor link project.
    

Problem conclusion

  • when build record for the chained build id is not existed in
    DB, pass the failure result to runwait
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM54084

  • Reported component name

    BUILD FORGE SE

  • Reported component ID

    5724S2705

  • Reported release

    712

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-12-11

  • Closed date

    2012-02-24

  • Last modified date

    2012-02-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BUILD FORGE SE

  • Fixed component ID

    5724S2705

Applicable component levels

  • R712 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSB2MV","label":"Rational Build Forge"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
24 February 2012