APAR status
Closed as program error.
Error description
If a report Prompt Page has a page query, the Execution Method property cannot be set to Concurrent. In addition, any prompt queries that are shared by 2 or more prompts cannot have an Execution Method of Concurrent when there is a Page Query. ??ERROR MESSAGE?RSV-SRV-0040 An application error has occurred. Contact your Administrator. ?Details ?CCLAssertError:0:Fatal: CCL_ASSERT_NAMED(m_bAllRowsOptimization == false, "The master dataset cannot be re-used for a second iterator if AllRows optimization was applied when the query was executed.");
Local fix
Set Query property - Query Hings > Execution Method = Sequential .
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos 10 Business Intelligence 10.1.1 Fix * * Pack 1 * ****************************************************************
Problem conclusion
Code Fix
Temporary fix
Comments
APAR Information
APAR number
PM51814
Reported component name
COG8 BI REPORT
Reported component ID
5724W12RS
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-08
Closed date
2012-07-24
Last modified date
2012-07-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COG8 BI REPORT
Fixed component ID
5724W12RS
Applicable component levels
RA11 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"","label":""}}]