A fix is available
APAR status
Closed as program error.
Error description
The user installed the Rational Cobol Runtime product and wanted to run the customization clists. Some of the clists invoke ISREDIT MACROs. Due to the Edit profile setting (AUTOSAVE OFF) the macros could not update the file being edited when they exited with ISREDIT END command. The workaround was to add ISREDIT SAVE before the ESREDIT END command manually. This should be fixed in the shipped macros the same way. The macros are: ELACCHNG ELADELT ELSJOBCD
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL USERS OF RATIONAL COBOL RUNTIME - RBD * **************************************************************** * PROBLEM DESCRIPTION: MACRO ERROR RUNNING RUNTIME * * CUSTOMIZATION CLIST * **************************************************************** * RECOMMENDATION: APPLY THIS MAINTENANCE * **************************************************************** MACRO ERROR RUNNING RUNTIME CUSTOMIZATION CLIST
Problem conclusion
DUE TO THE EDIT PROFILE SETTING (AUTOSAVE OFF) THE MACROS COULD NOT UPDATE THE FILE BEING EDITED WHEN THEY EXITED WITH ISREDIT END COMMAND. THE WORKAROUND WAS TO ADD ISREDIT SAVE BEFORE THE ESREDIT END COMMAND MANUALLY.
Temporary fix
Comments
APAR Information
APAR number
PM51735
Reported component name
RATL COBOL RT Z
Reported component ID
5655R2900
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-07
Closed date
2012-01-16
Last modified date
2012-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ELACHNG ELADELT ELAJOBCD
Fix information
Fixed component name
RATL COBOL RT Z
Fixed component ID
5655R2900
Applicable component levels
R601 PSY UK75483
UP12/01/26 P F201
Fix is available