Error description
RPT test generation takes almost 40 times longer in RPT 8.2.0.5 vs 8.1.1.2 due to auto data correlation
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** RPT test generation takes almost 40 times longer in RPT 8.2.0.5 vs 8.1.1.2 due to auto data correlation
Problem conclusion
RPT now provides an eclipse.ini flag to allow customers to revert automatic data correlation handling of brackets in requests to RPT 8.1.1.x behavior. This can be much faster in some cases. Use -DrptDCSkipBrackets=True in the eclispe.ini.
Temporary fix
Comments
APAR Information
APAR number
PM50019
Reported component name
PERF TESTER WIN
Reported component ID
5724J9601
Reported release
820
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-10-13
Closed date
2011-11-11
Last modified date
2011-11-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PERF TESTER WIN
Fixed component ID
5724J9601
Applicable component levels
R820 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Line of Business":{"code":"LOB45","label":"Automation"}}]