IBM Support

PM45633: selecting default RCR with specific OLE throws DXL errors

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When selecting the default RCR for a module with a specific OLE
    object will throw the following
    error:
    
    -R-E- DXL: ?standard/changemgnt/Utils/ecpsutils.inc:3697? null
    string
    parameter was passed into argument position 2
    
    Backtrace:
    
    ?standard/changemgnt/Utils/ecpsutils.inc:4020?
    
    ?standard/changemgnt/Utils/ecpsutils.inc:4080?
    
    ?standard/changemgnt/Utils/ecpsutils.inc:6445?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1350?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1930?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:2062?
    
    ?Line:26?
    
    -I- DXL: execution halted
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The problem was being caused when calling the DOORS perm
    richTextWithOle(object."Object Text") with an object
    containing a specific OLE.
    
    The following DXL error appears during this call:
    
    -R-E- DXL: ?standard/changemgnt/Utils/ecpsutils.inc:3697?
    null string
    parameter was passed into argument position 2
    
    Backtrace:
    
    ?standard/changemgnt/Utils/ecpsutils.inc:4020?
    
    ?standard/changemgnt/Utils/ecpsutils.inc:4080?
    
    ?standard/changemgnt/Utils/ecpsutils.inc:6445?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1350?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1930?
    
    ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:2062?
    
    ?Line:26?
    
    -I- DXL: execution halted
    

Problem conclusion

  • Instead of calling compressedBuffer(Buffer buf, string file)
    with Buffer buf = containing the result from the
    richTextWithOle call, we are now calling
    compressedRichTextWithOle(object."Attribute", string file)
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM45633

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    930

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-12

  • Closed date

    2011-09-28

  • Last modified date

    2011-09-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R930 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: