A fix is available
APAR status
Closed as program error.
Error description
When selecting the default RCR for a module with a specific OLE object will throw the following error: -R-E- DXL: ?standard/changemgnt/Utils/ecpsutils.inc:3697? null string parameter was passed into argument position 2 Backtrace: ?standard/changemgnt/Utils/ecpsutils.inc:4020? ?standard/changemgnt/Utils/ecpsutils.inc:4080? ?standard/changemgnt/Utils/ecpsutils.inc:6445? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1350? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1930? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:2062? ?Line:26? -I- DXL: execution halted
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The problem was being caused when calling the DOORS perm richTextWithOle(object."Object Text") with an object containing a specific OLE. The following DXL error appears during this call: -R-E- DXL: ?standard/changemgnt/Utils/ecpsutils.inc:3697? null string parameter was passed into argument position 2 Backtrace: ?standard/changemgnt/Utils/ecpsutils.inc:4020? ?standard/changemgnt/Utils/ecpsutils.inc:4080? ?standard/changemgnt/Utils/ecpsutils.inc:6445? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1350? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:1930? ?standard/changemgnt/record_mode/rcm_open_trigger.dxl:2062? ?Line:26? -I- DXL: execution halted
Problem conclusion
Instead of calling compressedBuffer(Buffer buf, string file) with Buffer buf = containing the result from the richTextWithOle call, we are now calling compressedRichTextWithOle(object."Attribute", string file)
Temporary fix
Comments
APAR Information
APAR number
PM45633
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-12
Closed date
2011-09-28
Last modified date
2011-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]