IBM Support

PM40530: RFT8202 : FF Browser -CRFCP0055E: Unable to set text in a read-only text area, while using setProperty('.value').

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Tools: RFT8202 / 8201 / 8202 iFix001
    Browser: IE8
    OS: Win XP SP3
    
    Problem description:
    
    Setting a value in the HTML text field using setProperty (for
    example)
    
    userInputs[0].setProperty('.value', 'widget_searchBoxNode');
    
    Throws : exception_context = setProperty() called on
    TextGuiTestObject(Ref:RemoteProxyReference{testContext:193ee001d
    fcbc,
    objectId:159, testObjectClass:TextGuiTestObject}).
    exception_name =
    com.rational.test.ft.UnableToPerformActionException
    exception_message = CRFCP0055E: Unable to set text in a
    read-only text area
    Script playback cannot be completed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    RFT8202|FF Browser Invalid error message "CRFCP0055E: Unable
    to set text in a read-only text area, while using
    setProperty(".value")." is thrown during playback
    

Problem conclusion

  • Added check for the browser before checking for unsupported
    property.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM40530

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-01

  • Closed date

    2011-09-16

  • Last modified date

    2011-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RAT FUNC TESTER

  • Fixed component ID

    5724G2503

Applicable component levels

  • R820 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSJMXE","label":"Rational Functional Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
27 October 2021