Error description

  • Import a file with empty string-values using the TI and
    batchupdate-mode. If the string-values are not empty everything
    works fine. An empty string-value can not be written into a cell
    of a cube (can not overwrite the old value)  ? therefore the old
    value remains in the cell and will be read be a CellGetS ?
    that?s wrong.????Hint:??If you disable the batchupdate-mode
    (batchupdatestart and batchupdatefinishwait(0) ), die TI-import
    works fine.??
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos TM1 9.5.1 FP1 or Upgrade to IBM Cognos *
    * TM1 9.5.2 FP1 or Upgrade to IBM Cognos TM1 10.1.0            *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM38499

  • Reported component name

    TM1 TURBO INTEG

  • Reported component ID

    5724W49TI

  • Reported release

    952

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-05

  • Closed date

    2012-02-15

  • Last modified date

    2012-02-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TM1 TURBO INTEG

  • Fixed component ID

    5724W49TI

Applicable component levels

  • R951 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
21 September 2021