  • Closed as program error.

Error description

  • In RFT 8.2.0.1 and IE8 compatibility view browser mode,
    customer is seeing problem where the
    'document.setAjaxTrace(true)' fails with
    com.rational.test.ft.TargetGoneException and causes the IE8
    browser tab to crash.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    'document.setAjaxTrace(true)' causes crash in IE8
    Compatibility view browser mode
    

Problem conclusion

  • In Compatibility View, Internet Explorer 8 reports version
    vector, document mode, and user agent string as if it is
    Internet Explorer 7;however, the user agent string also
    includes a token indicating that the browser is really
    Internet Explorer 8.
    Previously we were checking version vector to insert
    XDomainRequest wrapperScript into Broswer based on some
    conditional check for IE8 version.
    I have done changes to Include a new conditional check to
    check for token "Trident/4.0"  which remains same in IE8
    mode and in compatibility view mode.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM37950

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-28

  • Closed date

    2011-06-29

  • Last modified date

    2011-06-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RAT FUNC TESTER

  • Fixed component ID

    5724G2503

Applicable component levels

  • R820 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSJMXE","label":"Rational Functional Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
27 October 2021