APAR status
Closed as program error.
Error description
having 2 projects, A and B being externally connected having in each project a requirement type for external traceability customers main idea is to do traces from A to B this scenario describes what the customer does if he finds a wrong traceability link from B to A in project B do a trace from a requirement within B to a requirement in A (link in wrong direction) goto project A in the trace window of requirement in A, remove the from value and then afterward add a to value, save after having done both actions (delete and add). open the properties of that requirement again dubbleclick on the traced to requirement you see a window showing circular trace (see screenshot) problem could be seen on customers machine ReqPro 7.1.1.4 problem could be seen on latest ReqPro releases 7.1.1.5 and 7.1.2.2 problem could be seen with Access and DB2 database
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Rational RequisitePro client for Windows allows circular traces in a special scenario. This happens when in the same step the user removes and adds a trace to a requirement of an external project.
Problem conclusion
RequisitePro was modified to ensure the trace to a requirement of an external project is correctly removed in the case where the user is removing and adding a trace in the same step.
Temporary fix
Comments
APAR Information
APAR number
PM36209
Reported component name
REQUISITEPRO WI
Reported component ID
5724G3900
Reported release
711
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-04-04
Closed date
2011-06-22
Last modified date
2011-06-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
REQUISITEPRO WI
Fixed component ID
5724G3900
Applicable component levels
R711 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHCT","label":"Rational RequisitePro"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: