IBM Support

PM36190: RFT 8201 : Recoder do not emit java code for VP image

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The issue is also reproducible in house using the latest RFT
    8.2.0.1 iFix1 against ClassicJavaA application
    
    Steps to reproduce:
    - Enable simplified scripting
    - Make sure that the 'Skip verification points' option in RFT
    preferences is unchecked
    - Record a new script that launch IE and go to ClassicJavaA
    application
    - Create an image VP by using an option 'Click on the Camera
    icon below to capture the screen image.'
    - Create another text VP on the order button
    - Playback the script
    -? The text VP works properly. The image VP does not show up in
    the log. No error message
    
    The problem is, there is no java script emitted during recording
    itself, hence playback obviously would fails. We need to
    investigate why java code is not getting emitted for screen
    image vp. For now, there is a workaround available. The
    workaround is manully use custom code and then add a VP code
    within a custom block. Please see the escalation for more
    details.
    
    Please note this problem only occurs when you use an option
    'Click on the Camera icon below to capture the screen image.'
    The problem does occurs when you use 'Using the mouse, click the
    Object Finder icon'.
    
    Expected results: Recorder should be able to emit Java code for
    image VP
    Actual results: Recorder does not emit the Java code
    automatically.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Java code was not being generated for the screen capture
    verification point and hence, we couldn't playback the
    operation. Made appropriate changes to take care of such
    non-mapped test objects.
    

Problem conclusion

  • Java code corresponding to screen capture VP is generated as
    expected and we are able to playback the script.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM36190

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    811

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-04

  • Closed date

    2011-09-16

  • Last modified date

    2011-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RAT FUNC TESTER

  • Fixed component ID

    5724G2503

Applicable component levels

  • R811 PSN

       UP