APAR status
Closed as program error.
Error description
A Transformer Model that used to work in version 8.4, on the same database and same volume of data, in now unable to complete the cube build in version 10.??After 5 hours, it fails at the end of the cube update with a TR0112 There isn't enough memory available.????A workaround to this issue would be to disable MultiProcessing in file cogtr.xml or in a -d option added to command-line??but the customer absolutely reject this possibility for the following reasons :??- this increases batch process time whereas all batches must be processed during the night and they are already short in time on that server.??- they are afraid that other models suddenly encounter that same problem.????Particularities about this model :??- about 1.3 millions of categories??- datasource is based on one package. There are two requests : one structural, one factual.
Local fix
A workaround to this issue would be to disable MultiProcessing i n file cogtr.xml or in a -d option added to command-line but t he customer absolutely reject this possibility for the following reasons : - this increases batch process time whereas all bat ches must be processed during the night and they are already sho rt in time on that server. - they are afraid that other models suddenly encounter that same problem.
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos Business Intelligence 10.1 Refresh * * Pack 1 * ****************************************************************
Problem conclusion
Code Fix
Temporary fix
Comments
APAR Information
APAR number
PM35819
Reported component name
COG8 BI TRANSFO
Reported component ID
5724W12TR
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-29
Closed date
2011-09-13
Last modified date
2011-09-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COG8 BI TRANSFO
Fixed component ID
5724W12TR
Applicable component levels
RA11 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCRGHX","label":"Transformer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
13 September 2011