Error description
In RDz v8.0.x, A Property Group that is created but isn't associated with a z/OS Project / MVS Subproject disappear following an exit/restart of RDz client.
Local fix
Problem summary
The problem is a timing issue: when the Property Group Manager (PG Mgr) view tries to display the Property Groups for a system, the internal system registry (SR) may not have been completely populated. The reason the Property Group associated with a subproject shows up is that we keep a backup copy of the Property Group with the subproject so that they can be exported/imported together. The timing issue is caused by our PG Mgr listening for slightly different events than the SR so that the PG Mgr was getting notified of a new RSE CONNECTION being loaded at startup and it was trying to get info about it from the SR while the SR. Meanwhile, the SR was getting notified of a new RSE SUBSYSTEM being loaded which is related to a CONNECTION but might arrive later than the CONNECTION notification. When that happens, there is no system in the SR when the PG Mgr asks the SR for it. This is causing the missing PGs.
Problem conclusion
The logic in the PG Mgr is changed so that it listens for SUBSYSTEMS like the SR does. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.0.2 Refresh Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM33795
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-28
Closed date
2011-05-17
Last modified date
2011-05-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R801 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
27 October 2020