Fixes are available
Rational ClearCase Fix Pack 03 (8.0.0.3) for 8.0
Rational ClearCase Fix Pack 11 (8.0.0.11) for 8.0
Rational ClearCase Fix Pack 12 (8.0.0.12) for 8.0
Rational ClearCase Fix Pack 13 (8.0.0.13) for 8.0
Rational ClearCase Fix Pack 14 (8.0.0.14) for 8.0
Rational ClearCase Fix Pack 15 (8.0.0.15) for 8.0
Rational ClearCase Fix Pack 16 (8.0.0.16) for 8.0
Rational ClearCase Fix Pack 17 (8.0.0.17) for 8.0
Rational ClearCase Fix Pack 18 (8.0.0.18) for 8.0
Rational ClearCase Fix Pack 19 (8.0.0.19) for 8.0
Rational ClearCase Fix Pack 20 (8.0.0.20) for 8.0
Rational ClearCase Fix Pack 21 (8.0.0.21) for 8.0
APAR status
Closed as unreproducible in next release.
Error description
Reference count issue between MVFS mnode and NFS vnode causes a panic on release of an mnode with a bad vnode reference ClearCase 7.0.1.9 AIX 6.1TL3 Backtrace: CRASH INFORMATION: CPU 13 CSA F00000002FF47600 at time of crash, error code for LEDs: 70000000 pvthread+01FE00 STACK: [04FE38AC]nfs.ext:nfs_check_close_for_dio_cio@AF123_76+00008C (0000000000000000, 0000000004000001 [??]) [05099454]nfs.ext:nfs3_close+000214 (??, ??, ??, ??, ??, ??) [04FD335C]nfs.ext:aix2onc_close+00007C (??, ??, ??, ??) [004BDBD4]vnop_close+000094 (??, ??, ??, ??) [052C60E4]mvfs.o:mfs_aix_vnop_close+000040 (F100011030754838, 0400000104000001, 0000000100000001, 0000000000000000, F100011022CE1C7C) [052D8168]mvfs.o:mvfs_closev_ctx+000210 (F100010069D283D0, 0400000104000001, 0000000100000001, 0000000000000000, F100011022CE1C7C, 0000000000000000) [052D6E20]mvfs.o:mfs_closev+000048 (F100010069D283D0, 0400000104000001 0000000100000001, 0000000000000000, F100011022CE1C7C) [052C3C58]mvfs.o:mfs_aix_close+000034 (F100010069D283D0, 0000000004000001, 0000000000000000, F100011022CE1C7C) [004BDBD4]vnop_close+000094 (??, ??, ??, ??) [005267D0]vno_close+000050 (??) [0053FF44]closef+000064 (??) [004A0E98]closefd+0000F8 (??, ??) [004A12AC]closex+0002AC (??, ??) [004A159C]close+00011C (??) [00003844].svc_instr+000144 () Workaround: None
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Reference count issue between MVFS mnode and NFS vnode causes a panic on release of an mnode with a bad vnode reference.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PM29587
Reported component name
CLEARCASE UNIX
Reported component ID
5724G2901
Reported release
701
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-27
Closed date
2012-04-11
Last modified date
2012-04-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLEARCASE UNIX
Fixed component ID
5724G2901
Applicable component levels
R712 PSY
UP
Document Information
Modified date:
11 April 2012