IBM Support

PM28202: FOR THE SHORT TEXT ELEMENT FIELD IN WCM AUTHORING UI, THE NUMBER OF CHARACETRS ARE NOT VALIDATED FOR NON-ENGLISH DATA

 

APAR status

  • Closed as program error.

Error description

  • In the short text element filed, WCM Authoring UI does not
    validate the length of the text enter if the number of
    characters are beyond 250 chars for non-english or mixed
    language. Does not return a valid error or warning when attempt
    to save.
    

Local fix

Problem summary

  • Problem Summary:
     PM28202 FOR THE SHORT TEXT ELEMENT FIELD IN WCM AUTHORING UI,
    THE NUMBER OF CHARACTERS ARE NOT VALIDATED FOR NON-ENGLISH
    
    Detailed Problem Description:
    When a user enters non-english text for example text with French
    Accent characters saving the item can fail with the following
    error:
    
    Error while calling a function createItems of PLS data manager.
    The user is unaware why the save failed.
    
    Problem Analysis:
    French accent characters are more than 1 byte the short text
    field is limited to 250 bytes.  The input field is limited to
    250 characters but when WCM attempts to store the item it fails
    because the field although 250 characters or less is still
    larger than 250 bytes.
    

Problem conclusion

  • Problem Solution:
    Code has been added to validate the short text field vale and if
    greater than 250 bytes truncate the text before save and display
    a warning message.
    
    Affected Users:
    All users .
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM28202

  • Reported component name

    LOTUS WEB CONT

  • Reported component ID

    5724I2900

  • Reported release

    615

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-12-06

  • Closed date

    2010-12-14

  • Last modified date

    2010-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LOTUS WEB CONT

  • Fixed component ID

    5724I2900

Applicable component levels

  • R61A PSY

       UP

  • R61B PSY

       UP

  • R61C PSY

       UP

  • R610 PSY

       UP

  • R615 PSY

       UP

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1.5","Edition":"","Line of Business":{"code":null,"label":null}}]

Document Information

Modified date:
09 September 2020