  • Closed as program error.

Error description

  • The purpose of the Metric Designer project is to create a metric
    extract to extract the scorecard hierarchy and metric values
    from a Framework Manager package import source. The scorecards
    created will run an Analysis Studio report passing the scorecard
    external id as a parameter so that the report is run in context
    from each scorecard. In order to achieve this the scorecard id
    must be set to the MUN as this is the only parameter accepted by
    Analysis Studio reports.????As the MUN is only available from a
    dimensional package using the roleValue function, the project
    uses a dimensional model and the scorecard id is set to the MUN
    using the roleValue('_memberUniqueName', level) function in a
    metric extract. ????When the extract is executed the scorecard
    structure is only partially created and no metric data values
    are generated.????If the extract is modified to use a different
    item as the scorecard id then the scorecard structure and metric
    data is generated correctly but the Analysis Studio report
    cannot then be run in context.????It doesn't seem to be possible
    to create a metric extract to extract and load the scorecard
    structure and metric values if the scorecard id is set to be a
    MUN.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Metric Server 10.1 FP1.                           *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM25909

  • Reported component name

    COG8 BI METRIC

  • Reported component ID

    5724W12MS

  • Reported release

    840

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-04

  • Closed date

    2012-05-10

  • Last modified date

    2012-05-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    COG8 BI METRIC

  • Fixed component ID

    5724W12MS

Applicable component levels

  • RA10 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCRGHL","label":"Metrics Studio"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.4","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
10 May 2012