Error description
Administrator gets RMCA access rights on a private view when editing access on view 1) log in as user A, create Private view in a module 2) then log in as Administrator and open the same module 3) in the module open the Manage views window 4) edit the access for the Private view ie editing access for user A or adding user B 5) when clicking apply, a line appears showing that Administrator has RMCA rights on the view When user A then tries to open Manage Views window the following DXL error is generated: -R-E- DXL: ?standard/access/accessTab.inc:2131? An unexpected error has occurred: No access to the administrator account But the Access tab for the private view does not now show Administrator listed. If open Manage Views again as Administrator and check the Access for the same view, Administrator is listed along with the changes that were made. observed in 8.3, 9.2 and 9.3
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The defect was narrowed down to set and unset perms inconsistency. It was possible to add users but do not delete users from view if some other user had open this module for Exclusive write.
Problem conclusion
Implementation of unset(View, username) perm has been changed to fix this defect.
Temporary fix
Comments
APAR Information
APAR number
PM24882
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-10-20
Closed date
2011-03-31
Last modified date
2011-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R920 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
01 May 2020